Yes, the best place to stop the analysis is during the ethanol precipitation step.
After addition of 4 vols 95% EtOH pre-heated to 60°C, the precipitant solution can be covered and left over night.
Modified on: Wed, 10 Nov, 2021 at 12:52 PM
Yes, the best place to stop the analysis is during the ethanol precipitation step.
After addition of 4 vols 95% EtOH pre-heated to 60°C, the precipitant solution can be covered and left over night.